Runs of 15+ minutes at the full written rate, 5 minutes dropped at each end, the rest cut into 5-minute segments (SoC, temperature, rate / rated / battery_loss / rate scaling). A minute where the battery did not move, a forced export that did not reach the grid, or an exact 0 temperature reading breaks the run. grid_power loading is factored out of find_export_limited_minutes. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
… grids battery_rate_grid_update() builds the manual grid from the apps.yaml curves (fallback and prior), scans the history daily for grid evidence, keeps it in storage for a year and fits the learned grid; battery_rate_grid_auto (default on) lays it over the manual one. Two binary sensors (battery_charge/discharge_rate_grid) carry the source, evidence and a coarse grid. battery_temperature_charge_curve_auto is removed, and setting a manual curve no longer turns learning off. The old learners are unwired; their tests go (the temperature-cap rule tests move to test_battery_rate_grid). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The plan reads one 101-entry battery ceiling curve per step, picked from the charge/discharge rate grids by that step's forecast temperature (Prediction.rate_curves). The grids are derived on demand (PredBat.rate_grids), keyed on the curves, battery size and learned grids, so a tariff comparison or debug replay never plans with a stale one. The ceiling is absolute on a path at or below the rated rate (AC charge, export): a cold limit is the same kW on each. On a path above it (a hybrid's DC charge) the curve scales with the path, as the SoC curve did, because the history only measures the battery up to its rated rate. A request below the ceiling is never scaled. find_charge_rate and get_*_rate_curve take the curve in place of the SoC curve and temperature curve. The hot path uses per-curve cached lookups (rate_curve_function): keying one shared cache on the 101-entry curve cost 27%. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The kernel context's temperature cap arrays and single SoC curves become a small table of rate grid curve rows (102 wide: 101 SoC percents then the rated rate) and a row index per step; rate_curve_pct mirrors utils.rate_curve_ceiling. ABI 11 -> 12, parity revision 20 -> 22, all six binaries rebuilt with zig. Parity edge cases cover a forecast cooling through learned grid rows. The random scenario baseline is regenerated: 8 of 20 plans move because the template's 1 kW DC charge maximum is below the rated AC rate, so the DC path now uses the battery's absolute taper rather than 1 kW x the curve. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…D with a short table A status table for the two grids (source, cells, evidence days, temperature range, when learned, last scan), then each grid as a plotly 3D surface (SoC x temperature x rate / rated, gl3d bundle loaded on this page only) with the last 90 days' evidence segments as dots, and the grid at 10% SoC x 5 C as a table. The old ApexCharts curve charts go. Also: warmer than the evidence a learned grid is no longer capped by the manual grid - that made a warmer row slower than the warmest learned one (seen on fleet data: 1.00 at 35 C under 1.11 at 30 C). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…limmer colour bar Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ners The SoC curve finder and learner (and the path that logged a curve for apps.yaml), the temperature curve learner and overlay, the discharge temperature evidence, their sensors, attributes and constants are replaced by the rate grids. find_charge_curve's tests go with it; its export-limit cases move to the rate grid scan tests. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
apps-yaml.md gains a Battery rate grids section (learning, battery_rate_grid_auto, what is ignored, the exact-0 rule, fallback to the apps.yaml curves, the absolute ceiling and the hybrid DC exception, the sensors and the Curves page); the old auto-curve and temperature-learning text goes, the manual curve reference stays. FAQ, setup, customisation and web interface pages follow. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…nds, gaps, cache size, debug dumps - A store that does not read back is only treated as empty once its reads have failed on 3 cycles over 10 minutes; until then a save waits, so a storage outage cannot let one scan replace a year of evidence. - Discharge evidence needs grid_power history (an ignored forced export looks like a slow battery otherwise), and a charge minute needs grid import when there is history (a charge command ignored while PV charges the battery). - With no curve set in apps.yaml, gaps in the evidence are interpolated from the measured neighbours instead of leaning on the default grid, which filled them to the highest rate the rule allowed. - The per-curve lookup caches are bounded (64 curves x 2048 lookups); unbounded they could reach ~2 GB over weeks. - The year of evidence and the derived grids are kept out of debug dumps; replay rebuilds them from the learned grids. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…arned without temperature Review fixes: - A grid learned with no temperature (battery_temperature but no battery_temperature_history) was used at every temperature, dropping a manual temperature curve; it is now capped by it at each degree. - Below the evidence only the manual temperature cap applies, not the manual SoC curve (the learned rows carry the taper). - On a hybrid's DC path above the rated rate a learned grid scales with the path, but a manual temperature cap now stays absolute in kW, as it did before the grids: each curve row carries it as entry 102 (kernel rows 103 wide, parity revision 23, binaries rebuilt). - An exact 0 reading with a learned grid takes the manual exact-0 cap. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…try hourly, and keep long reads out of the history cache - battery_rate_grid_history_days (default 28): the first scan, and any until one has succeeded, reads this much history (as much as there is). battery_rate_grid_scan_days (default 2): later scans read this much - a day since the last plus a day's overlap - widened to cover a longer gap since the last successful scan, capped at the history setting. - A scan whose history read failed is retried after 60 minutes instead of a day, without losing the full first window. - A read longer than days_previous passes tracked=False, so the history cache does not keep (and refresh every cycle) 28 days of each sensor from then on. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ta pad option minute_data() and minute_data_state() fill every minute of the window they are asked for, padding the time before the oldest record. With the 28-day first scan and Home Assistant's default 10 days of history, the padded days counted as coverage, so the per-day merge removed stored evidence the scan never saw (and padding could form fake full-rate runs). Both functions gain pad (default True, unchanged for every other caller); the rate grid scan passes pad=False for every history it reads and stops at the shortest real history, temperature and grid_power included. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Owner
Author
|
Automated review failed to complete for this PR. Reason: Claude ran out of turns before finishing (--max-turns) (exit status 1). Failed at: |
springfall2008
enabled auto-merge (squash)
November 15, 2026 19:56
springfall2008
disabled auto-merge
November 15, 2026 19:57
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Why
The plan models the rate a battery achieves as
min(rated x SoC curve, temperature cap). Fleet data says the two interact: a cold battery starts tapering at a lower SoC. On one install the taper begins around 80% SoC at 28 C, around 60% at 20 C, and almost straight away at 12 C. No SoC curve plus temperature cap can represent that.A per-install rate grid (rate as a fraction of rated, by SoC and battery temperature), fitted by weighted least squares under a monotone rule, was tested against 26 fleet installs. Each model was fitted on 80% of the measured cells and scored on the rest, in 5 folds:
What changes
grid_power), an export-limited minute, or a temperature reading of exactly 0 (treated as missing).apps.yamlcurves (battery_*_power_curve, its_default,battery_temperature_*_curve) are converted into a grid and act as the fallback and prior. Below the evidence a manual cold curve still applies; Predbat never extrapolates a slower rate.battery_rate_grid_auto: Falseplans with the manual curves only. Setting a manual curve no longer turns learning off.battery_rate_grid_history_days(default 28) is what the first scan reads, and any scan until one succeeds.battery_rate_grid_scan_days(default 2) is what each daily scan reads, widened after a gap. A failed history read is retried after an hour. Reads longer thandays_previouspasstracked=False, so the history cache doesn't keep 28 days of each sensor afterwards.battery_temperature_charge_curve_auto(added in feat(battery): learn the temperature charge curve, keep auto SoC curves in storage and out of the cold #6189), the discharge temperature evidence, and their four sensors.binary_sensor.predbat_battery_charge_rate_gridandbinary_sensor.predbat_battery_discharge_rate_grid.Behaviour changes to note
find_battery_temperature_capis kept, so the default grid plans exactly as before.Speed (predbat_debug_agile1.yaml, 3 runs each)
The Python path was 27% slower at first, because a shared lru cache hashed the 101-entry curve on every lookup. Each curve now gets its own small-keyed cache (
utils.rate_curve_function).Review fixes (independent whole-branch review: 0 critical, 6 important)
grid_powerhistory, and a charge minute needs grid import when that history exists. An ignored command (the battery covering the house, or charging from PV only) is no longer learned as a slow battery.Deferred minors:
battery_rate_max_scalingchanges later.soc_maxrefits every cycle.Tests
New tests cover the grid maths, the scan (including failure filters, exact 0 and export limits), storage/fallback/sensors, the absolute ceiling, kernel parity with a cooling forecast crossing grid rows, and the Curves page. The quick suite and pre-commit pass, as do kernel parity and the debug and random goldens.
🤖 Generated with Claude Code