Skip to content

About

Home Assistant integration for FloLogic valves, built on FloLogic's official Web API

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

FloLogic for Home Assistant

Home Assistant integration for FloLogic leak-detection water shutoff valves, built on FloLogic's official Web API through pyflologic.

The Web API is new and covers less of the device than the mobile app does. ha-flologic-unofficial speaks the app's own protocol and reaches every setting; the two use different domains and can run side by side.

What you need

FloLogic issues Web API credentials on request: an API key and a company ID, and optionally a webhook signing secret (Dashboard → API Manager). One config entry covers the company, and every valve it can see becomes a device.

Entities, per valve

Entity Notes
valve Open or closed: whether the water is off, for any reason
select: Mode home / away / bypass / shutoff. Disabled can be read but not set through the Web API
number: Flow sensitivity oz/min. The only setting the Web API can write
sensor: Shutoff reason Why it is off: Shut off manually, Flow ran too long, Leak detected by sensor, Freeze protection…
sensor: Problem What else is wrong while the valve stays open
sensor: Status, Flow state, Temperature, Last flow change
binary_sensor: Water flow detected, Connectivity Connectivity stays available while the valve is offline
event: Event Only with callbacks on. FloLogic's typed events and reason codes

The settings the Web API reports but cannot change (home and away flow limits, bypass duration, pre-alert notice, both low-temperature thresholds, and whether each is enabled) appear as diagnostic sensors.

Shutoff reason is the one to automate on: a valve reports SHUTOFF whether you closed it or it closed itself, and only the reason tells a leak from a deliberate shutoff.

Not available through the Web API

The valve's name, signal strength, firmware, battery, temperature offset, no-flow notice, Auto Away, Delay Away, winter mode, guest mode, the notification history, and writing any setting other than mode and flow sensitivity. Devices are named FloLogic <VID>; rename them in Home Assistant. The VID is printed on the valve.

Updates: polling, or callbacks

The Web API has no push channel of its own, so by default the integration polls every 60 seconds. FloLogic documents no rate limit, so 30 seconds is the floor.

Callbacks make changes arrive within seconds. FloLogic calls a URL you register whenever a valve shuts off, changes mode, goes offline, raises a pre-alert and so on. The integration updates the valve from the callback at once, fires the event entity and a flologic_event bus event, then refreshes to confirm. To turn them on:

  1. Enter the webhook signing secret, at setup or later under Reconfigure. Unsigned callbacks are never accepted.
  2. Make Home Assistant reachable: Home Assistant Cloud (no open port needed), or an external HTTPS URL under Settings → System → Network.
  3. Configure the integration and switch on Receive callbacks.

Callbacks belong to the FloLogic company, and other consumers may have registered their own. The integration only ever adds and removes its own URL, and withdraws it when the entry is deleted or callbacks are switched off.

Signatures are checked against the URL that was registered, not the one the request arrives on, so a reverse proxy or the Cloud relay does not break verification.

Caveats worth reading before you automate

Short flows are invisible. On the same backend, three real auto-shutoffs on a 30 second limit never showed any flow before the valve tripped. Water flow detected may never turn on during a real event. Build leak automations on the valve, the shutoff reason, and the auto_shutoff event.

Low-temperature thresholds include the device's temperature offset, according to FloLogic. The app shows the raw threshold and the offset separately, so the numbers can differ while the offset is non-zero.

An away flow limit of 0 means water off. Away then allows no flow at all. The binary sensor Away turns water off says so.

Upgrading from ha-flologic 0.4.x

Before 0.5.0 this repository held the app-protocol integration under the same flologic domain. That integration now lives at ha-flologic-unofficial with the domain flologic_unofficial. An old entry cannot be carried over (it holds an email and password), so Home Assistant shows a repair issue for it. Delete it, and add FloLogic (Unofficial), FloLogic, or both.

Install

  1. HACS → ⋮ → Custom repositories, add https://github.com/pfeffed/ha-flologic with category Integration.
  2. Install FloLogic and restart Home Assistant.
  3. Settings → Devices & services → Add integration → FloLogic.

pyflologic is not on PyPI, so the integration ships its own copy under vendor/ and declares no requirements: nothing is downloaded at setup.

Development

uv sync
uv run pytest
uv run ruff check .
uv run python scripts/vendor.py --check   # is the vendored library current?

License

MIT