Skip to content

split consumer and cp standby threshold - #4204

Merged
LKuemmel merged 1 commit into
openWB:masterfrom
LKuemmel:fixes
Oct 28, 2026
Merged

LKuemmel merged 1 commit into
openWB:masterfrom
LKuemmel:fixes

Conversation

@LKuemmel

Copy link
Copy Markdown
Contributor

references #4203 (comment)

Copilot AI left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟢 Approval recommended

The load-specific threshold changes are covered by regression tests across the affected control paths, with no active review issues identified.

No open issues 🎉

What changed in this PR

This pull request separates standby-current thresholds for consumers and chargepoints, allowing low-power consumers to remain recognized as active while preserving the existing chargepoint behavior.

Changes:

  • Adds load-specific get_mean_current() behavior: 0.15 A for consumers and 0.5 A for chargepoints.
  • Updates counter, consumer, chargepoint, surplus-control, and common algorithm logic to use load-specific current calculations.
  • Adds regression coverage for small consumer currents and threshold behavior.
  • An unresolved boundary inconsistency remains for consumers reporting exactly 0.15 A; the mean-current calculation and charge_state classification use different comparisons.
File Description
packages/​control/​load_protocol.py Adds the shared load-specific mean-current implementation and default threshold. The exact-threshold comparison is inconsistent with consumer state classification.
packages/​control/​load_protocol_test.py Tests consumer and chargepoint threshold differences.
packages/​control/​counter.py Uses load-specific current calculations in counter handling.
packages/​control/​counter_test.py Covers small consumers with unknown phase configuration.
packages/​control/​consumer/​consumer.py Applies the consumer threshold when determining minimum and required current.
packages/​control/​consumer/​consumer_test.py Tests that small running consumers remain enabled.
packages/​control/​chargepoint/​chargepoint.py Uses the chargepoint-specific current calculation for logging.
packages/​control/​algorithm/​utils.py Makes the charging-current threshold configurable.
packages/​control/​algorithm/​utils_test.py Verifies the unchanged default threshold behavior.
packages/​control/​algorithm/​surplus_controlled.py Uses load-specific current values in surplus regulation.
packages/​control/​algorithm/​surplus_controlled_test.py Tests current limiting for small consumers.
packages/​control/​algorithm/​common.py Uses load-specific current values in load-management calculations.
packages/​control/​algorithm/​common_test.py Tests that small consumer current is retained during load management.

Review effort: Lite