6 changes: 6 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -52,6 +52,9 @@ Removed. `scripts/bump_version.py` turns them into a release section.

### Changed

- I-P conversions use one exact BTU factor (1 W = 3.41214 BTU/h, 1 TR = 3516.85 W) instead of a
mix of 3.412 and 1/0.293, so I-P values shown and entered (BTU, BTU/h, kBTU, TR, lb CO₂e/kBTU)
shift by up to 0.03 %; results in SI are unchanged (#227)
- Performance curve plots restyled: white background with light grid, legend above the plot,
outdoor air temperature labelled under both AWHP panels, unified hover, the part of a curve outside its operating limits drawn dashed, and the original
curves shown in grey behind a custom copy (#171)
Expand Down Expand Up @@ -86,6 +89,9 @@ Removed. `scripts/bump_version.py` turns them into a release section.

### Fixed

- Heat rejection/recovery capacities entered in BTU/h in the Edit Equipment Scenario modal were
stored slightly off (100000 showed as 100028.4) because saving and display used different
BTU/h factors (#227)
- Combined LRMER/SRMER/AER CO₂e rate columns in the results CSV were not converted (and had no
unit) in IP mode
- Applying load scaling repeatedly no longer compounds the scale factor
Expand Down
4 changes: 2 additions & 2 deletions notes/unit-conventions.md
Original file line number Diff line number Diff line change
Expand Up @@ -212,11 +212,11 @@ UNIT_MAP = {
AUTO_SCALE_CONFIG = {
"energy": {
"SI": [(1e9, "GWh"), (1e6, "MWh"), (1e3, "kWh")],
"IP": [(1e3/3.412, "kBTU")],
"IP": [(1e3 * BTU_to_Wh, "kBTU")],
},
"power": {
"SI": [(1e6, "MW"), (1e3, "kW")],
"IP": [(1e3/3.412, "kBTU/h")],
"IP": [(1e3 * BTUh_to_W, "kBTU/h")],
},
"power_cooling": {
"SI": [(1e6, "MW"), (1e3, "kW")],
Expand Down
18 changes: 6 additions & 12 deletions pages/equipment_page.py
Original file line number Diff line number Diff line change
Expand Up @@ -1041,9 +1041,12 @@ def save_edit_scenario(
if not new_name:
return True, no_update, "Scenario name cannot be empty."

from utils.units import BTUh_to_Wh, F_to_C, kWh_to_Wh
from utils.units import F_to_C, get_inverse_converter

unit_mode = unit_mode or "SI"
# exact inverse of the power converter open_edit_modal displays with (kW or BTU/h -> W),
# so a saved value reopens unchanged (#227)
power_to_base = get_inverse_converter("power", unit_mode)

if hr_wwhp_val == "None":
hr_wwhp_val = None
Expand Down Expand Up @@ -1079,22 +1082,13 @@ def save_edit_scenario(

if hr_eac_rejection_cap_W_val is not None:
try:
hr_eac_rejection_cap_W_val = float(hr_eac_rejection_cap_W_val)
if unit_mode == "IP":
hr_eac_rejection_cap_W_val = BTUh_to_Wh(hr_eac_rejection_cap_W_val)
else:
# convert back to base W, because SI unit for power is kW not W
hr_eac_rejection_cap_W_val = kWh_to_Wh(hr_eac_rejection_cap_W_val)
hr_eac_rejection_cap_W_val = power_to_base(float(hr_eac_rejection_cap_W_val))
except (ValueError, TypeError):
hr_eac_rejection_cap_W_val = None

if hr_eac_recovery_cap_W_val is not None:
try:
hr_eac_recovery_cap_W_val = float(hr_eac_recovery_cap_W_val)
if unit_mode == "IP":
hr_eac_recovery_cap_W_val = BTUh_to_Wh(hr_eac_recovery_cap_W_val)
else:
hr_eac_recovery_cap_W_val = kWh_to_Wh(hr_eac_recovery_cap_W_val)
hr_eac_recovery_cap_W_val = power_to_base(float(hr_eac_recovery_cap_W_val))
except (ValueError, TypeError):
hr_eac_recovery_cap_W_val = None

Expand Down
4 changes: 2 additions & 2 deletions pages/loads_page.py
Original file line number Diff line number Diff line change
Expand Up @@ -1151,7 +1151,7 @@ def update_table(

if hhw_range and len(hhw_range) == 2:
if unit_mode == "IP":
# kBTU/h → W (1 kBTU/h = 1e3 BTU/h = 1e3/3.412 W)
# kBTU/h → W (1 kBTU/h = 1e3 BTU/h = 1e3 * BTUh_to_W W)
w_per_kbtu = 1e3 / W_to_BTUh
hhw_range = [h * w_per_kbtu for h in hhw_range]
else:
Expand Down Expand Up @@ -1333,7 +1333,7 @@ def update_slider_units(unit_mode):
area_max = int(sqm_to_sqft(area_max_si))
area_step = 5000

# Convert HHW: W → kBTU/h (1 kBTU/h = 1e3 BTU/h = 1e3/3.412 W)
# Convert HHW: W → kBTU/h (1 kBTU/h = 1e3 BTU/h = 1e3 * BTUh_to_W W)
# Using kBTU/h to avoid excessively large numbers
kbtu_per_w = W_to_BTUh / 1e3 # W to kBTU/h
hhw_min = round(hhw_min_si * kbtu_per_w, 1)
Expand Down
32 changes: 16 additions & 16 deletions utils/units.py
Original file line number Diff line number Diff line change
@@ -1,12 +1,14 @@
# any constants used in the analysis
# unit conversions
# all are multiplied, right to left
ton_to_W = 12000 * 0.293 # refrigerant-ton to W
BTUh_to_W = (
1055.05585262 / 3600
) # BTU/hr to W (IT BTU, ≈ 0.29307); every BTU factor derives from this
W_to_BTUh = 1 / BTUh_to_W # ≈ 3.41214
BTU_to_Wh = BTUh_to_W # same factor: BTU to Wh is BTU/h to W
Wh_to_BTU = W_to_BTUh
ton_to_W = 12000 * BTUh_to_W # refrigerant-ton to W (≈ 3516.85)
W_to_ton = 1 / ton_to_W
BTUh_to_W = 0.293 # BTU/hr to W
W_to_BTUh = 1 / BTUh_to_W
Wh_to_BTU = 3.412
BTU_to_Wh = 1 / Wh_to_BTU
lbs_to_ton = 0.454 / 1000 # lbs (e.g. of CO2) to metric tons
ton_to_lbs = 1 / lbs_to_ton
lb_to_kg = 0.454 # lbs (e.g. of CO2) to metric tons
Expand Down Expand Up @@ -45,11 +47,11 @@ def kWh_to_Wh(kWh):


def Wh_to_BTUh(Wh):
return Wh * 3.412
return Wh * Wh_to_BTU


def BTUh_to_Wh(BTUh):
return BTUh / 3.412
return BTUh * BTU_to_Wh


def kg_to_lbs(kg):
Expand Down Expand Up @@ -387,11 +389,10 @@ def sqft_to_sqm(sqft):
(1e3, 1e3, "kWh"), # >= 1 kWh (in Wh) → kWh
],
"IP": [
# 1 Wh = 3.412 BTU; kBTU = 1e3 BTU
# Threshold: 1 kBTU = 1e3 BTU = 1e3/3.412 Wh ≈ 293.083 Wh
# Scale: divide Wh by (1e3/3.412) to get kBTU
# (1e3 / 3.412, 1e3 / 3.412, "kBTU"),
(1e3 / 3.412, 1e3 / 3.412, "kBTU"),
# kBTU = 1e3 BTU
# Threshold: 1 kBTU = 1e3 * BTU_to_Wh ≈ 293.07 Wh
# Scale: divide Wh by (1e3 * BTU_to_Wh) to get kBTU
(1e3 * BTU_to_Wh, 1e3 * BTU_to_Wh, "kBTU"),
],
},
"energy_electric": {
Expand All @@ -414,10 +415,9 @@ def sqft_to_sqm(sqft):
(1e3, 1e3, "kW"), # >= 1 kW (in W) → kW
],
"IP": [
# 1 W = 3.412 BTU/h; kBTU/h = 1e3 BTU/h
# Threshold: 1 kBTU/h = 1e3/3.412 W ≈ 293.083 W
# (1e3 / 3.412, 1e3 / 3.412, "kBTU/h"),
(1e3 / 3.412, 1e3 / 3.412, "kBTU/h"),
# kBTU/h = 1e3 BTU/h
# Threshold: 1 kBTU/h = 1e3 * BTUh_to_W ≈ 293.07 W
(1e3 * BTUh_to_W, 1e3 * BTUh_to_W, "kBTU/h"),
],
},