From 8edc46dbb8c12096c463ac07e9e46739ce89abf3 Mon Sep 17 00:00:00 2001 From: t-kramer Date: Tue, 17 Nov 2026 11:36:33 -0800 Subject: [PATCH] fix: address #227 --- CHANGELOG.md | 6 ++++++ notes/unit-conventions.md | 4 ++-- pages/equipment_page.py | 18 ++++++------------ pages/loads_page.py | 4 ++-- utils/units.py | 32 ++++++++++++++++---------------- 5 files changed, 32 insertions(+), 32 deletions(-) diff --git a/CHANGELOG.md b/CHANGELOG.md index 9e1a3a5..508595f 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -52,6 +52,9 @@ Removed. `scripts/bump_version.py` turns them into a release section. ### Changed +- I-P conversions use one exact BTU factor (1 W = 3.41214 BTU/h, 1 TR = 3516.85 W) instead of a + mix of 3.412 and 1/0.293, so I-P values shown and entered (BTU, BTU/h, kBTU, TR, lb CO₂e/kBTU) + shift by up to 0.03 %; results in SI are unchanged (#227) - Performance curve plots restyled: white background with light grid, legend above the plot, outdoor air temperature labelled under both AWHP panels, unified hover, the part of a curve outside its operating limits drawn dashed, and the original curves shown in grey behind a custom copy (#171) @@ -86,6 +89,9 @@ Removed. `scripts/bump_version.py` turns them into a release section. ### Fixed +- Heat rejection/recovery capacities entered in BTU/h in the Edit Equipment Scenario modal were + stored slightly off (100000 showed as 100028.4) because saving and display used different + BTU/h factors (#227) - Combined LRMER/SRMER/AER CO₂e rate columns in the results CSV were not converted (and had no unit) in IP mode - Applying load scaling repeatedly no longer compounds the scale factor diff --git a/notes/unit-conventions.md b/notes/unit-conventions.md index 94bcbed..994e955 100644 --- a/notes/unit-conventions.md +++ b/notes/unit-conventions.md @@ -212,11 +212,11 @@ UNIT_MAP = { AUTO_SCALE_CONFIG = { "energy": { "SI": [(1e9, "GWh"), (1e6, "MWh"), (1e3, "kWh")], - "IP": [(1e3/3.412, "kBTU")], + "IP": [(1e3 * BTU_to_Wh, "kBTU")], }, "power": { "SI": [(1e6, "MW"), (1e3, "kW")], - "IP": [(1e3/3.412, "kBTU/h")], + "IP": [(1e3 * BTUh_to_W, "kBTU/h")], }, "power_cooling": { "SI": [(1e6, "MW"), (1e3, "kW")], diff --git a/pages/equipment_page.py b/pages/equipment_page.py index c83ca78..cc77c38 100644 --- a/pages/equipment_page.py +++ b/pages/equipment_page.py @@ -1041,9 +1041,12 @@ def save_edit_scenario( if not new_name: return True, no_update, "Scenario name cannot be empty." - from utils.units import BTUh_to_Wh, F_to_C, kWh_to_Wh + from utils.units import F_to_C, get_inverse_converter unit_mode = unit_mode or "SI" + # exact inverse of the power converter open_edit_modal displays with (kW or BTU/h -> W), + # so a saved value reopens unchanged (#227) + power_to_base = get_inverse_converter("power", unit_mode) if hr_wwhp_val == "None": hr_wwhp_val = None @@ -1079,22 +1082,13 @@ def save_edit_scenario( if hr_eac_rejection_cap_W_val is not None: try: - hr_eac_rejection_cap_W_val = float(hr_eac_rejection_cap_W_val) - if unit_mode == "IP": - hr_eac_rejection_cap_W_val = BTUh_to_Wh(hr_eac_rejection_cap_W_val) - else: - # convert back to base W, because SI unit for power is kW not W - hr_eac_rejection_cap_W_val = kWh_to_Wh(hr_eac_rejection_cap_W_val) + hr_eac_rejection_cap_W_val = power_to_base(float(hr_eac_rejection_cap_W_val)) except (ValueError, TypeError): hr_eac_rejection_cap_W_val = None if hr_eac_recovery_cap_W_val is not None: try: - hr_eac_recovery_cap_W_val = float(hr_eac_recovery_cap_W_val) - if unit_mode == "IP": - hr_eac_recovery_cap_W_val = BTUh_to_Wh(hr_eac_recovery_cap_W_val) - else: - hr_eac_recovery_cap_W_val = kWh_to_Wh(hr_eac_recovery_cap_W_val) + hr_eac_recovery_cap_W_val = power_to_base(float(hr_eac_recovery_cap_W_val)) except (ValueError, TypeError): hr_eac_recovery_cap_W_val = None diff --git a/pages/loads_page.py b/pages/loads_page.py index 375fc16..afb6880 100644 --- a/pages/loads_page.py +++ b/pages/loads_page.py @@ -1151,7 +1151,7 @@ def update_table( if hhw_range and len(hhw_range) == 2: if unit_mode == "IP": - # kBTU/h → W (1 kBTU/h = 1e3 BTU/h = 1e3/3.412 W) + # kBTU/h → W (1 kBTU/h = 1e3 BTU/h = 1e3 * BTUh_to_W W) w_per_kbtu = 1e3 / W_to_BTUh hhw_range = [h * w_per_kbtu for h in hhw_range] else: @@ -1333,7 +1333,7 @@ def update_slider_units(unit_mode): area_max = int(sqm_to_sqft(area_max_si)) area_step = 5000 - # Convert HHW: W → kBTU/h (1 kBTU/h = 1e3 BTU/h = 1e3/3.412 W) + # Convert HHW: W → kBTU/h (1 kBTU/h = 1e3 BTU/h = 1e3 * BTUh_to_W W) # Using kBTU/h to avoid excessively large numbers kbtu_per_w = W_to_BTUh / 1e3 # W to kBTU/h hhw_min = round(hhw_min_si * kbtu_per_w, 1) diff --git a/utils/units.py b/utils/units.py index a54212c..51053eb 100644 --- a/utils/units.py +++ b/utils/units.py @@ -1,12 +1,14 @@ # any constants used in the analysis # unit conversions # all are multiplied, right to left -ton_to_W = 12000 * 0.293 # refrigerant-ton to W +BTUh_to_W = ( + 1055.05585262 / 3600 +) # BTU/hr to W (IT BTU, ≈ 0.29307); every BTU factor derives from this +W_to_BTUh = 1 / BTUh_to_W # ≈ 3.41214 +BTU_to_Wh = BTUh_to_W # same factor: BTU to Wh is BTU/h to W +Wh_to_BTU = W_to_BTUh +ton_to_W = 12000 * BTUh_to_W # refrigerant-ton to W (≈ 3516.85) W_to_ton = 1 / ton_to_W -BTUh_to_W = 0.293 # BTU/hr to W -W_to_BTUh = 1 / BTUh_to_W -Wh_to_BTU = 3.412 -BTU_to_Wh = 1 / Wh_to_BTU lbs_to_ton = 0.454 / 1000 # lbs (e.g. of CO2) to metric tons ton_to_lbs = 1 / lbs_to_ton lb_to_kg = 0.454 # lbs (e.g. of CO2) to metric tons @@ -45,11 +47,11 @@ def kWh_to_Wh(kWh): def Wh_to_BTUh(Wh): - return Wh * 3.412 + return Wh * Wh_to_BTU def BTUh_to_Wh(BTUh): - return BTUh / 3.412 + return BTUh * BTU_to_Wh def kg_to_lbs(kg): @@ -387,11 +389,10 @@ def sqft_to_sqm(sqft): (1e3, 1e3, "kWh"), # >= 1 kWh (in Wh) → kWh ], "IP": [ - # 1 Wh = 3.412 BTU; kBTU = 1e3 BTU - # Threshold: 1 kBTU = 1e3 BTU = 1e3/3.412 Wh ≈ 293.083 Wh - # Scale: divide Wh by (1e3/3.412) to get kBTU - # (1e3 / 3.412, 1e3 / 3.412, "kBTU"), - (1e3 / 3.412, 1e3 / 3.412, "kBTU"), + # kBTU = 1e3 BTU + # Threshold: 1 kBTU = 1e3 * BTU_to_Wh ≈ 293.07 Wh + # Scale: divide Wh by (1e3 * BTU_to_Wh) to get kBTU + (1e3 * BTU_to_Wh, 1e3 * BTU_to_Wh, "kBTU"), ], }, "energy_electric": { @@ -414,10 +415,9 @@ def sqft_to_sqm(sqft): (1e3, 1e3, "kW"), # >= 1 kW (in W) → kW ], "IP": [ - # 1 W = 3.412 BTU/h; kBTU/h = 1e3 BTU/h - # Threshold: 1 kBTU/h = 1e3/3.412 W ≈ 293.083 W - # (1e3 / 3.412, 1e3 / 3.412, "kBTU/h"), - (1e3 / 3.412, 1e3 / 3.412, "kBTU/h"), + # kBTU/h = 1e3 BTU/h + # Threshold: 1 kBTU/h = 1e3 * BTUh_to_W ≈ 293.07 W + (1e3 * BTUh_to_W, 1e3 * BTUh_to_W, "kBTU/h"), ], }, "power_cooling": {